1. 918博天堂·(中国区)首页

    Module

    • Supports 2 door control. It can connect with access controller via RS-485
    • Connects with card reader via RS-485 (OSDP) or Wiegand
    • Installs with guide rail
    • Supports battery charging and discharging
    • Supports indicators for indicating power status, communciation status, running status, and door staus
    View Less
    View more
    Sales Inquiry

    Available models:

    DS-K2M002X
    DS-K2M002X

    Spezifikation

    • System
    • BetriebssystemMCU
    • Schnittstelle
    • Lock control2
    • Schaltfläche Beenden2
    • Türkontakt Eingang2
    • Alarm-Eingang4
    • Alarm-Ausgang2
    • SAOBTAGE1
    • RS-4854, 2 for card reader, 2 for access controller
    • Wiegand2, standard 26/34 input, supports custom Wiegand settings
    • Kapazität
    • Linked door capacity2 doors
    • Linked card reader capaciry4 RS-485 card readers (OSDP protocol) and 2 Wiegand card readers
    • Allgemein
    • Indikator6 indicators, 1 for indicating power status, 1 for running status, 2 for communication status, and 2 for door status
    • BatterieCharge and discharge
    • Stromversorgung12 ± 15% VDC
    • Leistungsaufnahme≤ 50 W
    • Betriebstemperatur-10 °C to 55 °C (14 °F to 131 ° F)
    • Betriebsfeuchtigkeit0% to 90% (No condensing)
    • InstallationInstallation with guide rail
    • Funktion
    • Configuration via Web browserSupport via access controller
    • Multi-Faktor-AuthentifizierungSupport via access controller
    • Erste Person inSupport via access controller
    • Multi-door interlockingSupport via access controller: supports 32 groups (32 doors each)

    Spezifikation

    Spezifikation
    System
    • BetriebssystemMCU
    Schnittstelle
    • Lock control2
    • Schaltfläche Beenden2
    • Türkontakt Eingang2
    • Alarm-Eingang4
    • Alarm-Ausgang2
    • SAOBTAGE1
    • RS-4854, 2 for card reader, 2 for access controller
    • Wiegand2, standard 26/34 input, supports custom Wiegand settings
    Kapazität
    • Linked door capacity2 doors
    • Linked card reader capaciry4 RS-485 card readers (OSDP protocol) and 2 Wiegand card readers
    Allgemein
    • Indikator6 indicators, 1 for indicating power status, 1 for running status, 2 for communication status, and 2 for door status
    • BatterieCharge and discharge
    • Stromversorgung12 ± 15% VDC
    • Leistungsaufnahme≤ 50 W
    • Betriebstemperatur-10 °C to 55 °C (14 °F to 131 ° F)
    • Betriebsfeuchtigkeit0% to 90% (No condensing)
    • InstallationInstallation with guide rail
    Funktion
    • Configuration via Web browserSupport via access controller
    • Multi-Faktor-AuthentifizierungSupport via access controller
    • Erste Person inSupport via access controller
    • Multi-door interlockingSupport via access controller: supports 32 groups (32 doors each)

    Resources

    Technical documents

    Data Sheet
    Quick Start Guide
    For better user experience, we highly recommend you to update your device to the latest firmware asap.
    Kompatibel mit:
    DS-K2M002X

    Deutschsprachige Dokumente

    Herunterladen
    Herunterladen
    Vertrieb
    Newsletter Anmeldung
    Chatbot
    Bezugsquellen
    Website Feedback
    Website Feedback
    Kontakt
    Hik-Partner Pro close
    Hik-Partner Pro
    Security Business Assistant. At Your Fingertips. Learn more
    Hik-Partner Pro
    Scan and download the app
    Download
    Hik-Partner Pro
    Hik-Partner Pro

    Get a better browsing experience

    You are using a web browser we don’t support. Please try one of the following options to have a better experience of our web content.