Traffic Signal Controller

  • Modular design method,easy to install and maintain
  • Using controllable silicon to control the signal light,keeping the device stable
  • Using open, standard communication protocol, easy to extend
  • Equipped with display and control panel, which can real-time monitor and manually adjust the signal status
  • Auto-monitoring system for the communication modules and lights. It will automatically alert and react to any problems that arise
  • Equipped with independent yellow flash controller,enhancing the security;
  • Manually control the on and off of a channel/a light separately, which is convenient for wiring inspection during debugging and lamp status inspection during maintenance
  • Support online upgrades without interrupting the running of the scheme
  • Log level: debug, info, warning, error, fault
View Less
View more

Available models:

DS-TSC300-44H/HK3
DS-TSC300-44H/HK3
NEW

Specification

  • Function
  • Signal Control Board and Channel4 output board(s), supporting 44 channel(s)
  • Timing StrategySupporting 64 phases, 255 patterns, 64 plans, 255 Schemes(Adjustable on demand)
  • Signal Control Mode•Fixed Cycle: A preset time is given to each movement every cycle, Multiple phase/cycle parameters can be set in different time periods. •Full-Actuated: Real-time optimization of green light timing based on traffic data, such as lane flow, in all lanes at the intersection. •Semi-Actuated: Based on traffic data in certain lanes, such as flow, it provides real-time optimization of the green light duration for the main lanes and reduces the unnecessary green light duration for the secondary lanes. •Self-Adaptive: For congested intersection scenarios, calculate and optimize the cycle and phase durations based on historical traffic data of the all lanes to Improve the traffic efficiency. •Single-Point Optimization: According to historical and real-time traffic data, timing parameters are calculated in advance and adjusted in real time during running. •Coordinates Green wave: Consider the linkage of multiple intersections, set parameters such as phase difference, and ensure that vehicles in the main direction encounter green lights all the way. •Pedestrian Crossing: Adjust signal timing based on pedestrian in demand. •Special control: Light Disable, Yellow Flash and All red.
  • Control TypeLocal mode,web control,HCM control,manual key control,third-party platform control
  • Manual ControlAuto, Manual, Step-to-Step, Yellow Flash, All Red and Special Directional control
  • Web ConfigurationSupports web browser configuration, 3D interface display of the real-time status of the intersection
  • Time SynchronizationSupports NTP time synchronization, satellite time synchronization (GPS antenna installation required), manual time configuration, and third-party platform time synchronization
  • Countdown Timer AccessSelf-learning mode,Pulse countdown,National standard 2004/2014 mode
  • Network
  • Network ProtocolTCP/IP,HTTP,NTP, IPv4,802.1X,UDP
  • ClientHikCentral Master Lite,Hik-Central Master
  • Web BrowserChrome V61+,IE9 to IE11,Firefox V41+,Edge
  • APIconnect to the HCM through the OpenAPI,or connect the device throught NTCIP
  • SecurityPassword protection,Complicated password,802.1X authentication (EAP-PEAP, EAP-LEAP, EAP-MD5),IP address filter,Host authentication (MAC address),Security audit log,Basic and digest authentication for HTTP/HTTPS
  • Interface
  • Ethernet Interface 1 RJ45 10M/100M self-adaptive Ethernet interface
  • RS-4852 × RS-485 interface(s)
  • RS-2321 × RS-232 interface(s)
  • USB1 × USB 2.0
  • Alarm Supports 8-ch pedestrian button input(s)
  • Control Panel13 buttons: auto, manual, step-to-step, yellow flash, all red and special directional control buttons
  • Wireless Controller (Optional)5 buttons: Auto, manual, all red, yellow flash, and step-by-step control, or button customization
  • GPS (Optional)( Optional ) Support GPS Satellite Signal Real-time Timing
  • General
  • Power OutputAC 100 V to 240 V,50/60 Hz
  • Power InputAC 100 V to 240 V,50/60 Hz
  • Overall Power Consumption≤ 35 W (no load)
  • Signal Channel Consumption≤400W@AC220V;≤200W@AC110V
  • Insulation Resistance≥ 100 MΩ
  • Backup Power SupplySupports manual switching of main and backup power supply
  • Operating Condition-40 °C to 70 °C (-40 °F to 158 °F). Humidity: 95% or less (non-condensing)
  • Storage Condition-40 °C to 70 °C (-40 °F to 158 °F). Humidity: 95% or less (non-condensing)
  • Installation ModeFloor-standing
  • Net WeightApprox. 86.1 kg (189.82 lb.)
  • Gross WeightApprox. 93 kg (205.03 lb.)
  • Dimensions (Without Package)680 mm × 500 mm × 1081.8 mm (26.77" × 19.69" × 42.59") (L × W × H)
  • Dimensions (with Package)870 mm × 670 mm × 1270 mm (34.25" × 26.38" × 50.00") (L × W × H)
  • Cabinet MaterialSECC
  • Approval
  • EMCEN 50293:2012
  • SafetyEN IEC:62311-1:2021,EN IEC:62311-2:2021
  • EnvironmentCE-RoHS: 2011/65/EU
  • ProtectionIK10: IEC 62262:2002,IP54: IEC 60529-2013

Specification

Specification
Function
  • Signal Control Board and Channel4 output board(s), supporting 44 channel(s)
  • Timing StrategySupporting 64 phases, 255 patterns, 64 plans, 255 Schemes(Adjustable on demand)
  • Signal Control Mode•Fixed Cycle: A preset time is given to each movement every cycle, Multiple phase/cycle parameters can be set in different time periods. •Full-Actuated: Real-time optimization of green light timing based on traffic data, such as lane flow, in all lanes at the intersection. •Semi-Actuated: Based on traffic data in certain lanes, such as flow, it provides real-time optimization of the green light duration for the main lanes and reduces the unnecessary green light duration for the secondary lanes. •Self-Adaptive: For congested intersection scenarios, calculate and optimize the cycle and phase durations based on historical traffic data of the all lanes to Improve the traffic efficiency. •Single-Point Optimization: According to historical and real-time traffic data, timing parameters are calculated in advance and adjusted in real time during running. •Coordinates Green wave: Consider the linkage of multiple intersections, set parameters such as phase difference, and ensure that vehicles in the main direction encounter green lights all the way. •Pedestrian Crossing: Adjust signal timing based on pedestrian in demand. •Special control: Light Disable, Yellow Flash and All red.
  • Control TypeLocal mode,web control,HCM control,manual key control,third-party platform control
  • Manual ControlAuto, Manual, Step-to-Step, Yellow Flash, All Red and Special Directional control
  • Web ConfigurationSupports web browser configuration, 3D interface display of the real-time status of the intersection
  • Time SynchronizationSupports NTP time synchronization, satellite time synchronization (GPS antenna installation required), manual time configuration, and third-party platform time synchronization
  • Countdown Timer AccessSelf-learning mode,Pulse countdown,National standard 2004/2014 mode
Network
  • Network ProtocolTCP/IP,HTTP,NTP, IPv4,802.1X,UDP
  • ClientHikCentral Master Lite,Hik-Central Master
  • Web BrowserChrome V61+,IE9 to IE11,Firefox V41+,Edge
  • APIconnect to the HCM through the OpenAPI,or connect the device throught NTCIP
  • SecurityPassword protection,Complicated password,802.1X authentication (EAP-PEAP, EAP-LEAP, EAP-MD5),IP address filter,Host authentication (MAC address),Security audit log,Basic and digest authentication for HTTP/HTTPS
Interface
  • Ethernet Interface 1 RJ45 10M/100M self-adaptive Ethernet interface
  • RS-4852 × RS-485 interface(s)
  • RS-2321 × RS-232 interface(s)
  • USB1 × USB 2.0
  • Alarm Supports 8-ch pedestrian button input(s)
  • Control Panel13 buttons: auto, manual, step-to-step, yellow flash, all red and special directional control buttons
  • Wireless Controller (Optional)5 buttons: Auto, manual, all red, yellow flash, and step-by-step control, or button customization
  • GPS (Optional)( Optional ) Support GPS Satellite Signal Real-time Timing
General
  • Power OutputAC 100 V to 240 V,50/60 Hz
  • Power InputAC 100 V to 240 V,50/60 Hz
  • Overall Power Consumption≤ 35 W (no load)
  • Signal Channel Consumption≤400W@AC220V;≤200W@AC110V
  • Insulation Resistance≥ 100 MΩ
  • Backup Power SupplySupports manual switching of main and backup power supply
  • Operating Condition-40 °C to 70 °C (-40 °F to 158 °F). Humidity: 95% or less (non-condensing)
  • Storage Condition-40 °C to 70 °C (-40 °F to 158 °F). Humidity: 95% or less (non-condensing)
  • Installation ModeFloor-standing
  • Net WeightApprox. 86.1 kg (189.82 lb.)
  • Gross WeightApprox. 93 kg (205.03 lb.)
  • Dimensions (Without Package)680 mm × 500 mm × 1081.8 mm (26.77" × 19.69" × 42.59") (L × W × H)
  • Dimensions (with Package)870 mm × 670 mm × 1270 mm (34.25" × 26.38" × 50.00") (L × W × H)
  • Cabinet MaterialSECC
Approval
  • EMCEN 50293:2012
  • SafetyEN IEC:62311-1:2021,EN IEC:62311-2:2021
  • EnvironmentCE-RoHS: 2011/65/EU
  • ProtectionIK10: IEC 62262:2002,IP54: IEC 60529-2013

Resources

Technical documents

Quick Start Guide
User Manual
For better user experience, we highly recommend you to update your device to the latest firmware asap.
Applied to:
DS-TSC300-44H/HK3
Contact Us
Hik-Partner Pro close
Hik-Partner Pro
Security Business Assistant. At Your Fingertips. Learn more
Hik-Partner Pro
Scan and download the app
Download
Hik-Partner Pro
Hik-Partner Pro

Get a better browsing experience

You are using a web browser we don’t support. Please try one of the following options to have a better experience of our web content.