918博天堂·(中国区)首页

    How To Guide

    Filter
    faq filter close
    Category:
    All
    ACCESS CONTROL
    ALARM PRODUCTS
    DVR
    ITS
    NETWORK CAMERAS
    NETWORK PRODUCTS
    NVR
    SOFTWARE
    THERMAL PRODUCTS
    TRANSMISSION AND DISPLAY PRODUCTS
    TURBO HD CAMERA
    VIDEO INTERCOM
    • Please follow this article to use Attendance Service on HikCentral Connect

    • There are 3 ways to to configure VCA of the NVR:

      1. Video Struturalization.

      2. Face capture and recognition.

      3. Perimeter protection configuration.

    • Since version 4.63, NVR supports access to solar cameras by OTAP protocol, and realizes the functions of preview, video uploading, video retrieval and power display of solar cameras.

    • Please follow this article to install and configure the H8 Parking Management Camera.

    • There are 3 steps to configure false alarm analysis of 3 series semi self-learning camera:

      1. Configure events and collect false alarm pictures.

      2. Import false alarm pictures.

      3. Enable False Alarm Analysis.

       

    •  If you want to 26 series controller trigger the fire alarm interface after linking other access control devices to open the door, you can follow these instructions:

      1. Check the equipment arming status.

      2. Configuration linkage.

    • For face misidentification, the basic troubleshooting mainly includes checking the firmware, checking the face parameters, and checking the face registration picture. After completing the above basic operations, then let the person to identify and check the recognition effect again. If there are still problems, please collect information according to the attached template .

    • There are two ways to configure the villa door station using the AP Mode:

       1. Enable the AP function on the door station’s Webpage.

      2. Entering the AP mode by long-press the call button.

    • There are two ways to trigger alarm output of indoor station:

      1. Zone alarm :when zone alarm is detected, it will trigger alarm output of indoor station

      2. Calling linkage: when door station or other indoor station calls indoor station, it will trigger alarm output 

    • 1. Add Devices on iVMS-4200

      2. Batch register Indoor station to Door station

    • 1. Add Devices on iVMS-4200

      2. Add Indoor Station to Door Station

      3. Configure the Second lock on the Door Station

    • People Counting is used to calculate the number of people entered or left a certain configured area and form in daily/weekly/monthly/annual reports for analysis. 

    • As for some DVR models which supports Lite Mode, we can enable Lite Mode in the local GUI. I will take how to enable 1080P lite mode as example.

    • This document guide user to recover the password on DVR on local GUI.

    • 1. Connect DVR and Analog PTZ Camera

      2. Parameters Configuration

      3. Configuration test

    • To meet customers’ requirement for connecting analog and IP cameras in different rate, Hikvision Turbo HD DVR provide the function of disabling analog channels to expand IP channels. This document is mainly to introduce how to achieve this function.

      Notă: 1. Different series device have different abilities of expanding IP channels. You can refer to the file for more details. 2. Disabling one analog channel can expand one IP channels.  

    • To use POS function, both DVR and POS server should be configured and you can configure DVR locally or via iVMS-4200.

    • To use POS function, both DVR and POS server should be configured and you can configure DVR locally or via iVMS-4200.

    • An internet connected device (camera, DVR, NVR) can be configured to be accessed from outside its local network. Using an IP address allocated by the internet provider, the end user is able to connect to this device. Internet services for non-enterprise solutions commonly provide a dynamic IP address to its users. The lack of a static IP address means the user must reconfigure their device connection settings every time a new IP address is allocated. Managing multiple devices will prove difficult if IP addresses are constantly changing. This issue can be solved by using a Dynamic Domain Name System (DDNS) Service. A fixed address is assigned by the DDNS service provider that can be used to connect to the desired device. The device itself must be configured with the DDNS credentials so that it may automatically update the service with the newly allocated IP address. Through this service, devices under dynamic IP addresses can maintain static addresses. Hikvision products support a number of third party DDNS services in addition to HiDDNS/Hik-Connect. 

    • Heat map is a graphical representation of data represented by colors. The heat map function is usually used to analyze the visit times and dwell time of customers in a configured area.  

    • As for RAID 5, if one HDD is broken, the RAID5 will be in degraded mode, and we can rebuild RAID5 to recover data. If there are two HDDs broken, the RAID5 will be offline. 

    • NVR which supports NFS/iSCSI protocol can add up to 8 * 8T Net HDD including IPSAN or NAS.

      Notă: This function can be configured in website and local GUI.

    • The HDD Clone function can be used to copy the hard disk of NVR and back up the hard disk data of NVR. You need to log on NVR local GUI, then go to the Maintenance-HDD OperationHDD to configure.

    • The customer may have the request to save the video record backup.

      Notă: This function need more than two hard disks and the redundancy must be used in group mode. 

    • Please use the enterprise-class HDDs in HDD Compatible List for RAID function

    • Currently there are two ways to connect NVR with POS terminals, via network or via serial port. De exemplu: The NVR initiates the connection to the POS server for the POS data communications between POS server camera. 

    • Custom protocol is created by users with RTSP and 554 port. Then, IP cameras can be added to NVR by custom protocol to get naked stream. Notă: As for Hikvision cameras, the stream paths are as below. It is enough to fill in one kind of them. 

    • 1. Key Step 1---Enable the Ultra HD Resolution Mode

      2. Key Step 2---Follow the normal way of adding cameras to add the Ultra HD Resolution multi-track streams IP Camera

    • For NVR models which have independent output interface, if main output and auxiliary output have the different live view configuration. Even if auxiliary output don’t connect to screen, it will also waste some decoding ability of NVR.  

    • N+1 hot spare function is used for backup NVR. The maximum of ‘N’ is 32.

      Notă: This function is now supported by DS-9600NI-I series and DS-96000NI-I series NVR.

    • The smart playback function provides an easy way to get through the less effective information. When you select the smart playback mode, the system will analyze the video containing the motion or VCA information. It will mark it with red color and play it in normal speed, while the video without motion will be played in the 16-time speed(the speed function can be configurable, -E/-Q is not supported). The smart playback rules and areas are configurable.

      Notă: This speed function is now supported by almost all -K/-I/-super I series NVR.

    • Notă:

      1:There are two different ways to use NVR cloud storage function: NVR as Storage Server: It can be added to other HCP or NVRs. NVR as Client End: You can add Cloud Storage Server to the client NVR, such as Hikvision cloud 2.0 or another NVR (which is set as storage server). 

      2:For NVR Cloud Storage Function, the protocol we use is Hikvision Cloud 2.0, and it only support Hikvision Cloud 2.0. The 3rd party cloud storage services such as Google Cloud, Baidu Cloud and Ali Cloud are not supported. 

      3:It only supports the storage of alarm pictures and does not support any video or data. 

    • The function of HTTPS ensures the secure access of web services by adding digital signature certificate authentication. All series of NVRs support HTTPS function. This article takes k series NVR (DS-7608NI-K2 v4.30.061 build 210313) as an example to introduce how to use HTTPS function.

    • 1. Open the waterproof cap of the switch button. 

      2. Press and hold the switch button. 5s later, the image will be no video because the camera is rebooting and do not loosen the button when the camera is rebooting.

      3. Wait 2s after the image is stable again and then loosen the button (Do not loosen the button as soon as the image is normal). 

      •  In this case, camera model is DS-2CE10DF0T-PF
      •  DVR model is DS-7208HTHI-K2 4.21.000 build190722 ;DS-7108HGHI-F1 3.4.891build190121 
    • Connect the 3MP camera to DVR of HUHI models and you can operate locally or remotely

    • The PIR camera with O in the model name provides an alarm output interface (EXT ALARM OUTPUT), and an external alarm equipment can be connected to the interface. When you turn on the EXT ALARM OUTPUT and the PIR alarm is triggered, the external alarm device will also be triggered. We recommend that PIR camera and K series DVR be used together to provide more accurate alarm information. 

    • Preparation

      1. POC DVR: The end of model is /P. POC camera: The end of model is E

      2. Waterproof tape, HDD, HDMI/VGA cable, BNC cables, Network cables, Monitor, 

    • Preparation :

      1. NVR, IP camera

      2. Memory card, waterproof tape, HDD, HDMI cable, Network cables, Monitor, Switch

    • Preparation

      1. PoE NVR, IP camera

      2. Memory card, waterproof tape, HDD, HDMI cable, Network cables, Monitor. 

    • Preparation

      1. Wi-Fi kit or Wi-Fi NVR, Wi-Fi camera

      2. Memory card, waterproof tape, HDD, HDMI cable, Network cables, Monitor 

    • The full name of Hik-Connect DDNS is Hik-Connect Dynamic Domain Name Service. Once a device is added to a Hik-Connect account, the Hik-Connect DDNS server will allocate the device serial number as the default Hik-Connect domain name. Customer can edit the domain name later via Hik-Connect APP or web portal. Hik-Connect DDNS provides a mapping relationship between a domain and the device external IP & ports. 

    • Preparation:

      Turbo HD Cameras which belong to HxT series or UxT series can change the resolution of live view in camera OSD menu.

      1. Camera: DS-2CE16H0T-ITFS

      2. DVR: DS-7216HUHI-K2(S)

    • Preparation:

      1. DVR, Analog camera

      2. Waterproof tape, HDD, VGA cable, Coaxial cables, Monitor

    • Preparation :

      1. Camera: DS-2CE16H0T-ITFS

      2. DVR: DS-7216HUHI-K2(S)

    • Preparation :

      1. Camera mode: DS-2CE12DFT-PIRXOF

      2. DVR mode: DS-7216HUHI-K2 4.21.000 build190722

    • 1. Install TF card 

      2. Format TF card

      3. Set up the schedule 

      4. View Videos 

    • 1) Set LAN IP

      2) Set WLAN IP

      3) Login camera via WLAN

    • Preparation :

      SDKdemo tool downloaded from Hikvision Homepage

    • Preparation:

      1. Wi-Fi router, mobile phone

      2. Power up camera and waiting for the indicator light of camera quick flash blue

    • Preparation:

      1. DS-2CD21x5G0-IMS.

      2. Screw Driver x 1.

      3. Displayer with HDMI input.

      4. HDMI cable.

      5. HDMI switch cable (Type D-to-Type A).

    • The newly added Video Quality Diagnosis function in Basic Event supports 15 kinds of video quality detection functions which are Brightness Exception, Color Cast, Snow Interference, Stripe Interference, Image Freeze, Signal Loss, Clarity Exception, Image Flutter, Video Tampering, Blurred Screen, Image Noise, Light Spot, Image Purple Edge, ICR Exception, Protective Film Unremoved detection. 

      Each diagnosis function separately supports the setting of rules, linkage method and arming schedule. 

    • Preparation:

      1. FreeNFS tool.

      2. Specific Tcpdump file.

      3. SecureCRT.

    • 1. Set multicast address

      2. Set live view protocol

      3. Start Live View

    • 1. Min. Focus Distance  2. Lens Initialization  3. Preset   4. Patrol   5. Pattern

      6. Limit   7. Park Action 8. Scheduled Tasks    9. Smart Tracking   10. Focalizare rapidă

    • 1. Configure video stream

      2. Get stream on Firefox or Chrome

    • Camera Installation Requirements

      1. The height of the camera needs to be in the range of 2.5 m to 6 m.

      2. The tilt angle of the camera is recommended to be in the range of 25° to 60°.

      3. The best detection area is within 6 m of the horizontal distance from the camera. 

    • 1. Go to [configuration]-[Network]-[Advanced Settings]-[Integration Protocol], check the checkbox of Enable ONVIF 

      2. Click Add to create ONVIF user

      3. Create ONVIF user and use this username and password to login camera via ONVIF protocol

    • Hik-Connect is able to provide DDNS service for devices, through DONS cameras can be added to backend devices and use normal functions, such as live view, playback, recording.

    • 1. Open Me->Tools->Search for Important Firmware Update.

      2. Currently, the Hik-ProConnect APP supports two methods search for the device affected by security vulnerabilities. 

      3. If there is firmware to be upgraded, the device model and security firmware version will be prompted.

    • Hik-Connect app should be V4.3 or above. Supported device: Hikvision DVRs and NVRs. This function may vary according to the device model and current firmware version.

      1. The device has been added to your Hik-Connect account.

      2. Login the account that the device has been bound to.

      3. The device do not need to become Hik-Connect online.

    • 1) Add device through TCP/IP.

      2) Modify network center setting

      3) Modify uploading mode

      4) Add device again through EHOME protocol (not support sync face picture)

    • In this document, the access controller includes DS-K2600 series and DS-K2800 series access controllers.

    • 1) Set reader dip switch as wiegand mode.

      2) Connect DS-K2600 controller to RS485 reader

      3) Check reader LED status

    • This document displays guidance on how to enable advertisement mode in MinMoe access control terminal.

    • 1) Connect DS-K1201MF fingerprint reader to DS-K2600 access controller;

      2) Add fingerprint in iVMS-4200;

      3) Card management;

      4) Advanced function configuration;

      5) Synchronize permission to device;

      6) Swipe card and verify fingerprint

    • This document displays guidance on how to configure the required advertisement picture for MinMoe access control terminal in the web of this device with its IP.

    • This document displays guidance on how to configure QR code in IVMS4200 software and open door with it on MinMoe access control terminal.

    • Connecting card reader to access controll is mainly applied to swiping card or fingerprints to open the door for entering and exiting. 

    • Step 1: DIP Switch

      Step2:Wring 

      Step 3:Installation

    • 1) Connect DS-K1201MF fingerprint reader to DS-K2600 access controller;

      2) Add fingerprint in iVMS-4200;

      3) Card management;

      4) Advanced function configuration;

      5) Synchronize permission to device;

      6) Verify fingerprint or swipe card. 

    • This document displays guidance on how to call Hik-Connect mobile app from MinMoe access control terminal. 

    • This document is simply used to guide users how to wire correctly and ensure access controllers can control locks. The access controller model in this document is DS-K2604. Part 1 is mainly for magnetic lock wiring, and Part 2 and Part 3 are mainly for the situation that users could get the door status on iVMS-4200 Client.

    • 1. Access Control Devices 2600 series

      2. RS485 Card reader DS-K1108MK

      3. Card issuer DS-K1F100-D8

      4. iVMS4200 v3.2.0.10

    • 1) Set reader dip switch for RS485 address.

      2) Connect DS-K2600 controller to RS485 reader

      3) Check reader LED status

    • Connecting card reader to access controller is mainly applied to swiping card to open the door for entrring or exiting. 

    • This document displays guidance on how to configure PIN Code in IVMS4200 software and open door with it on MinMoe access control terminal

    • 1) Connect DS-K1201MF fingerprint reader to DS-K2600 access controller;

      2) Add fingerprint in iVMS-4200;

      3) Card management;

      4) Advanced function configuration;

      5) Synchronize permission to device;

      6) Verify fingerprint. 

    • SQL Server is a relational database management system introduced by Microsoft Corporation. It is easy to use and scalable, and has a high degree of integration with related software. It can be used across multiple platforms, from laptops running Microsoft Windows 98 to large multi-processor servers running Microsoft Windows Server 2012.

    • Connecting fingerprint card reader to access controll is mainly applied to swiping card or fingerprints to open the door for entering and exiting. 

    • 1) Power on DS-K2600 controller

      2) Connect controller to door sensor cable

    • 1) Add device to client software

      2) User management(Organization management)

      3) Apply permission to device

    • DS-K2600 series access controller can open all its doors when fire alarm signal triggers. Also, we can link other linkage actions such as buzzer or alarm output for fire alarm reactcion. Notă: Controller’s power supply must be cut off when doing all the hardware wiring steps.

    • 1) Add device through TCP/IP

      2) Modify network center setting

      3) Modify uploading mode

      4) Add device again through EHome protocol (not support sync face picture)

    • Connecting card reader to access controller is mainly applied to swiping card to open the door for entrring or exiting. 

    • In this document, the card enrollment station includes DS-K1F100-D8E and DS-K1F180-D8E; Make sure you have already got the V2.1.0 firmware and USB Demo for card enrollment station.

    • Connecting electric lock to access control terminal is mainly applied to open the door for exiting. 

    • Step1: Set dip switch for K1T501SF(instruction available on User manual)

      Step2: Add card and person info and sync to K2604 access controller.

      Step3: Test. Verify card on K1T501SF and check event from ivms-4200 software 

    • Operation Process:

      1) Power on DS-K2600 controller

      2) Connect controller to lock

    • 1) Confirm fire alarm signal type

      2) Select corresponding port to connect

      3) Test

    • 1) Find RS485+, RS485- according to the label in the back of device

      2) Modify device RS485 work mode

      3) Set RS485 address for reader

      4) Select related port and connect cables;

      5) Open door with registered card

    • 1) Select corresponding port to connect

      2) Test

    • 1) Power on DS-K2600 controller and connect lock to DS-K2600 controller

      2) Connect fire alarm signal to controller

    • 1) Wiring for standalone terminal.

      2) Edit permissions.

      3) Test

    • Connecting magnetic lock to access controller is mainly applied to swiping card to open the door for exiting.

    • 1) Add device through TCP/IP.

      2) Modify network center setting

      3) Modify uploading mode

      4) Add device again through EHOME protocol (not support sync face picture)

    • 1) What is Interlock function

      2) Interlock configuration

      3) Test

    • 1) Check lock type and select NC or NO wiring method.

      2) Select corresponding port to connect

      3) Test opening lock

    • Preparation: DS-K1T201 One secure module DS-K2M060

      Notă: Please cut off power supply before wiring and setting the DIP switch ;

    • Preparation:

      1. The model of optical fingerprint recorder is DS-K1F820-F;

      2. Please download the iVMS-4200 Client on Hikvision official website; http://www.hrbaojie.com/en/Tools_84.html

      And in this document, we use V2.7.0.6 iVMS-4200 Client;

    • Connect card reader to access controller is mainly applied to swiping card to open the door for entrring or exiting. 

    • 1) Add device to client software

      2) User management(Organization management)

      3) Apply permission to device

      4) Add authentication password

      5) Change reader verify mode 6) Test

    • Preparation:

      1. The card enrollment station includes DS-K1F100-D8E and DS-K1F180-D8E;

      2. Please download the iVMS-4200 Client on Hikvision official website; http://www.hrbaojie.com/en/Tools_84.html

      Notice:

      1. In this document, we use DS-K1F100-D8E card enrollment station;

      2. In this document, we use V2.7.0.6 iVMS-4200 Client;

    • 1) Alarm output/Doorbell wiring.

      2) Linkage configuration.

      3) Test

    • 1. Access Controller 2600 series

      2. Access Control Terminal

      3. Lock DS-K4E100 

    • Device Info:

      DS-K1T501SF firmware version: V1.1.0_build180202

      DS-K2604 firmware version: V2.0.4_build180913 

    •  1. Make sure VCA Resource Type has been selected with Temperature Measurement option as default.

      2. Make sure Display Temperature info option are enabled.

      3. Temperature measurement basic settings. Check the checkbox to enable temperature Measurement function.

      4. Temperature measurement normal mode

      5. Temperature measurement expert mode---Temperature Rule.

      6. Temperature measurement expert mode---Alarm Rule

    • 1. Make sure VCA Resource Type has been selected with Fire Detection option.

      2. Make sure Fire Point info are enabled.

      3.1 Fire Source Detection Basic Settings.

      3.2 Smoke Detection Basic Settings.

      4.1 Check the detected Fire source effect in live view.

      4.2 Check the detected smoke effect in live view.

    • Due to the feature of liquid crystal material, the color of LCD screens differs from each other when leaving the factory. So at project site, it is necessary to modify the color parameters to make them look same. This document is intended to introduce the method of how to modify color parameters of LCD large screen via remote control

    • This document is intended to introduce the method of how to use remote control to select screen ID of LCD large screen, change Input Source, do TEST, and configure with MENU. Connection of control cables and infrared probe will be introduced first before referring to the detailed operations 

    • When you look at this document, please understand the difference between the two versions first.

      Firmware version is the program version .To upgrade the firmware version, you need to use the .apk file to upgrade.

      System version is the keyboard operating system version. To upgrade it you need to use special update package.

      Please note that this document is written specifically for how to upgrade the system version. 

    • This document is intended to introduce the method of how to use remote control to select screen ID of LCD large screen, change Input Source, do TEST, and configure with MENU. Connection of control cables and infrared probe will be introduced first before referring to the detailed operations

    • Hikvision keyboard DS-1005KI support USB connection to computer and control over client software iVMS-4200. This document is intended to show the steps of how to use 1005KI with iVMS-4200. 

    • 3D22xxP is a full-managed network switch that support multiple access modes, including access through IP on webpage, through console port & telnet. This document is intended to show the method to access in different modes.

    • Preparation:

      1. IR receiver

      2. Control la distanță

      3. Video cable (HDMI,DP)

    • Preparation:

      1. DS-PWA Series AX PRO Wireless Security Control Panel

      2. IE explorer

      3. App Hik-Connect

    • When you want use Master Station Call Forwarding, you need connect two DS-PEA1-21 and one DS-PEA4L-7 to main master station DS-PEA4L-7 by SIP server at first. Then configure Master Station Call Forwarding in main master station. 

    • You can login the iVMS-4200 V3.1 Client Software to configure the device's parameters. You can also configure the security control panel's network parameters, alarm, permission, system, log search via the web client.

    • 1. Connect keypad to Security control panel.

      2. Connect Security control panel to iVMS-4200.

      3. Open remote configuration 

      4. Keypad operate 

    • 1. Find the port for PSTN module. 

      2. PSTN module connection.

      3. PSTN Configuration in iVMS-4200

      4. Operation 

    • 1. Add keyfob to the Control Panel

      2. Add Card to the Control Panel

      3. Delete Card

    • You can add two network cameras to the wireless security control panel, and link the camera with the selected zone for video monitoring. The following document will tell you how to configure event video transfer via Email settings to send Alarm Email. 

    • This document will tell you:

      1:How to power the wireless indoor siren

      2:How to add wireless indoor siren 

      3:How to reset the wireless indoor siren 

    • For Hybrid Panel, the difference user have different management permissions. Admin is like master manager,it can Enable permission for installer and manufacturer account. So we can use installer account or manufacturer account to upgrade firmware. 

    • To support DS-PHA Series Hybrid Security Control Panel, the Wired LCD Keypad need upgrade to newest firmware upgraded by RS232 cable or Hybrid Security Control Panel website. This document is guiding you how to upgrad by RS232 cable.

    • When you use Keypad to arm and disarm the Panel, if your authentication failed for the amount of configured time, the module will be locked for the programmed time duration. You can configure the Max failure time and locked duration in web interface.

    • When an alarm is triggered, if you want to send the alarm notification to mobile phone(SMS), you can set the notification push parameters. 

    • When AX Hub Wireless Control Panel can’t be searched in SADP, can’t ping IP successfully or the device is crashed. In this situation, AX Hub Wireless Control Panel need to be upgraded by RS232 cable.

    • You can login the iVMS-4200 Client Software to configure the device's parameters. You can also configure the security control panel's network parameters, alarm, permission, system, log search via the web client. 

    • 1. Connect keypad to Security control panel.

      2. Connect Security control panel to iVMS-4200.

      3. Open remote configuration

      4. Keypad operate

    • 1. Find the port for Output RS485 Expander Module. RS485 Expander Module & Keypad use same RS485 port. 

      2. RS485 Expander Module Connection Type and DIP address.

      3. Connect RS485 Expander Module to control panel.

      4. Check the Expander module Status in iVMS-4200 

      5. Check the Relay address in iVMS-4200 

    • 1. Check the license for Alarm input number and Alarm module. 

      2. Add DS-PWA32-HSR Wireless Security Control Panel to HikCentral.

      3. Configure Map.

      4. Configure Event and Alarm(Pop-Up).

      5. Configure HikCentral Client.

      6. Test Pop up.

      7. Control the System.

    • 1. Add Keypad to Control Panel

      2. Configure Keypad password

      3. Keypad Operation 

    • When you want pop-up windows in HikCentral Client,you need configure something by HikCentral website and Client.. 

    • AX Series Wireless Security Control Panel---AX Hub

    • If you want add wireless Peripherals (wireless detector, wireless keyfob, wireless siren) to the DS-PHA Panel, you need connect Wireless receiver DS-PM-RSWR at first. Then you can add the peripherals with web browser.

    • 1. Find the port for RS485 Expander Module.

      2. RS485 Expander Module Connection Type and DIP address.

      3. Connect RS485 Expander Module to control panel. 

      4. Check the Expander module Status in iVMS-4200

      5. Check the zone address in iVMS-4200

       

    • For AX PRO Panel, when you have add it to HPC (Hik-ProConnet) to manage, upgrade by Brower need PIN permissions from HPC browser.

    • Preparation:

      1. AX Series Wireless Security Control Panel,V1.0.2 or above

      2. Wireless output Expander DS-PM-WO2 or DS-PM-WO8 

    • 1. Find the port for Keypad. 

      2. Connect Keypad to control panel.

      3. Check the Keypad Status in iVMS-4200 

    • In order to separate the EN standard area and other areas, the customer can choose EN Standard or General standard, the choose interface need login Setter user.

    • When control panel is in disarm status, it shows “Zone Fault” for some zones. In this case, control panel can not arm system successfully.

    • Preparation :

      1. DS-PKOOM-LCD or DS-PK-L

      2. DS-19A series Network Security Control Panel or MBUS Security Control Panel

    • Preparation:

      1. PHA Series Hybrid Security Control Panel

      2. Internet Explorer 3. One SIM card and one Mobile Phone

    • This document will tell you :

      How to power the wireless water leak detector;

      How to add wireless water leak detector

      How to reset the wireless water leak detector

    • Preparation

      1. Hik-Connect Client:IOS:V3.6.0 180922 / Android:V3.6.1 180928 or above

      2. AX Series Wireless Security Control Panel,V1.0.0 or above

    • You can set the alarm center's parameters and all alarms will be sent to the configured alarm center. 

    • This document will tell you:

      How to power the wireless smoke detector

      How to add wireless smoke detector

      How to reset the wireless smoke detector

    • Preparation

      1. Pyronix Deltabell-X

      2. Pyronix Panel

      3. DS-19A series Network Security Control Panel or MBUS Security Control Panel

    • Preparation:

      1. DS-19A series Network Security Control Panel or MBUS Security Control Panel

      2. iVMS-4200 client

    • When DS-PHA Hybrid Control Panel can’t be searched in SADP, can’t ping IP successfully or the device is crashed. In this situation, Hybrid Control Panel need to be upgraded by RS232 cable.

    • This document will tell you:

      How to power the wireless temperature detector

      How to add wireless temperature detector

      How to reset the wireless temperature detector

    • Preparation:

      DS-19A series Network Security Control Panel or MBUS Security Control Panel

    • When you want to connect DS-PEA1-21 with DS-PEA4H-10 by SIP server,you need configure something by iVMS-4200.

    • Preparation:

      1. DS-PWA Series AX PRO Wireless Security Control Panel

      2. Wireless Keypad DS-PK1-E-WE

      3. IE explorer and App Hik-Connect

    • You can add two network cameras to the wireless security control panel, and link the camera with the selected zone for video monitoring. You can also receive and view the event video via client and Email.

    • When security control panel can’t be searched in SADP, can’t ping IP successfully or the device is crashed. In this situation, security control panel need to be upgraded by RS232 cable. 

    • This document will tell you:

      1:How to power the wireless outdoor siren

      2:How to add wireless outdoor siren 

      3:How to reset the wireless outdoor siren

    • Preparation

      1. Hik-Connect Client:IOS:V3.6.0 180922 / Android:V3.6.1 180928 or above

      2. AX Series Wireless Security Control Panel,V1.0.0 or above

    • Preparation:

      1. DS-PD1-EB Panic button

      2. DS-19A series Network Security Control Panel or MBUS Security Control Panel

    • To support AX Hub Wireless Control Panel 1.0.5 function, Wireless Output Expander DS-PM-WO2/8 support continuous output. In this situation, Wireless Output Expander DS-PM-WO2/8 need to be upgraded by RS232 cable.

    • When you want pop-up windows in HikCentral Client,you need configure something by HikCentral website and Client.

    • You can set the zone parameters on the zone page.

    • Preparation:

      1. DS-19A08-BNG Security Control Panel

      2. RS485 wireless Receiver Module DS-PM-RSWR

    • Preparation

      1. Wireless PIR Detector:DS-PD2-P10PW

      2. Wireless Magnetic Contact:DS-PD1-MC-WWS 3. Wireless Keyfob:DS-19K00-Y

    • You can login the iVMS-4200 V3.1 Client Software to configure the device's parameters. You can also configure the security control panel's network parameters, alarm, permission, system, log search via the web client.

    • You can login the iVMS-4200 Client Software to configure the device's parameters. You can also configure the security control panel's network parameters, alarm, permission, system, log search via the web client.

    • Preparation

      1. DS-19A08-01BNG MBUS Security Control Panel

      2. Single-zone Expander module DS-PM-MI1 

    • You can enable or disable SSH (Secure Shell) according to your actual needs. You can check serial port information by SSH.

    • Preparation:

      1. AX Series Wireless Security Control Panel,V1.0.2 or above

      2. iVMS-4200 client:2.8.2.2

    • The Auto-Arm / Disarm feature can only be set up within the Insite software. Provision is made to have Arm / Disarm periods for each day or for set Holidays so that a building can be automatically secured. To enable the Auto-Arm, select the “Add Action” tab and select the day(s). To each day adjust the ‘Arm’ and ‘Disarm’ times as required

    • Preparation:

      1. AX Series Wireless Security Control Panel, V1.0.4.(HIA_H10_EN_STD_V1.0.4_build191114)

      2. FSK Falcon GSM communicator.

      3. FSK to AxHub serial cable (Include in FSK packet).

      4. FSK simulation Software: Hikvision FSK Soft base

    • When an alarm is triggered, if you want to send the alarm notification to mobile phone(SMS or Voice call), you can set the notification push parameters. 

    • When Panic Alarm Station can’t be searched in SADP, can’t ping IP successfully or the device is crashed. In this situation, security control panel need to be upgraded by RS232 cable. Important

      Notă: Computer must close the firewall

    • For AX PRO Panel, Login by Browser need use Hik-Connect account and password, so you need add the device to Hik-connect at first. 

    • Preparation:

      1. AX Series Wireless Security Control Panel,V1.0.2 or above

      2. iVMS-4200 client:2.8.2.2

    • The Auto-Arm / Disarm feature can only be set up within the Insite software. Provision is made to have Arm / Disarm periods for each day or for set Holidays so that a building can be automatically secured. To enable the Auto-Arm, select the “Add Action” tab and select the day(s). To each day adjust the ‘Arm’ and ‘Disarm’ times as required.

    • After Hikvision shuts down iVMS-4500 and HiDDNS services, installers who previously used iVMS-4500 and HiDDNS services can add devices to Hik-ProConnect to provide remote operation, maintenance and management services for end users. Devices can be added to Hik-ProConnect through P2P and IP/Domain. This document will introduce them in detail.

    • With the termination of the service of Hik-Online, the devices previously registered in HiDDNS will not be able to use HiDDNS service for remote login and access again. It is recommended that users use Hik-Connect to add and access devices. Devices can be added into Hik-Connect App mainly through Cloud P2P, Hik-Connect DDNS and IP / domain, which will be introduced in detail in this document.

    • 1. Installation of 26xx series bullet camera junction box

      2. Installation of 27xx series dome junction box

      3. Installation of 2Hxx series bullet junction box

    • Preparation:

      1. Second generation AcuSense camera (-SL models).

      2. Custom audio with .wav format sampling rate as 8 KHz. 

    • 1) What is Interlock function

      2) Interlock configuration

      3) Test

    no result

    No matches found.

    Please check for errors or try new keywords.

    Contactați-ne
    Hik-Partner Pro close
    Hik-Partner Pro
    Hik-Partner Pro
    Scan and download the app
    Download
    Hik-Partner Pro
    Hik-Partner Pro

    Get a better browsing experience

    You are using a web browser we don’t support. Please try one of the following options to have a better experience of our web content.